FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.4.11  |  FHIR Version n/a  User: [n/a]

Resource StructureDefinition/FHIR Server from package de.medizininformatikinitiative.kerndatensatz.patho#2025.0.0-alpha2 (46 ms)

Package de.medizininformatikinitiative.kerndatensatz.patho
Type StructureDefinition
Id Id
FHIR Version R4
Source https://simplifier.net/resolve?scope=de.medizininformatikinitiative.kerndatensatz.patho@2025.0.0-alpha2&canonical=https://www.medizininformatik-initiative.de/fhir/ext/modul-patho/StructureDefinition/mii-pr-patho-specimen
Url https://www.medizininformatik-initiative.de/fhir/ext/modul-patho/StructureDefinition/mii-pr-patho-specimen
Version 2025.0.0
Status active
Name MII_PR_Patho_Specimen
Title MII PR Patho Specimen
Experimental False
Realm de
Description Pathology specimen (based on Biobank module)
Type Specimen
Kind resource

Resources that use this resource

CapabilityStatement
https://www.medizininformatik-initiative.de/fhir/ext/modul-patho/CapabilityStatement/metadata MII CPS Patho Capability Statement
https://www.medizininformatik-initiative.de/fhir/ext/modul-patho/StructureDefinition/mii-pr-patho-attached-image MII PR Patho Attached Image

Resources that this resource uses

StructureDefinition
http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-body-location-qualifier Body Location Qualifier Extension
http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-laterality-qualifier Laterality Qualifier Extension
https://www.medizininformatik-initiative.de/fhir/ext/modul-patho/StructureDefinition/mii-pr-patho-service-request MII PR Patho Service Request
https://www.medizininformatik-initiative.de/fhir/ext/modul-biobank/StructureDefinition/SpecimenCore Profile - Specimen - Bioprobe - Core
https://www.medizininformatik-initiative.de/fhir/ext/modul-biobank/StructureDefinition/Substance Profile - Substance - Additiv
https://www.medizininformatik-initiative.de/fhir/ext/modul-patho/ValueSet/mii-vs-patho-collection-method-snomed-ct MII VS Patho Collection Method [SNOMED CT]
https://www.medizininformatik-initiative.de/fhir/ext/modul-patho/ValueSet/mii-vs-patho-container-type-snomed-ct MII VS Patho Container Type [SNOMED CT]
https://www.medizininformatik-initiative.de/fhir/ext/modul-patho/ValueSet/mii-vs-patho-processing-procedure-snomed-ct MII VS Patho Processing Procedure [SNOMED CT]


Source

{
  "resourceType" : "StructureDefinition",
  "id" : "mii-pr-patho-specimen",
  "url" : "https://www.medizininformatik-initiative.de/fhir/ext/modul-patho/StructureDefinition/mii-pr-patho-specimen",
  "version" : "2025.0.0",
  "name" : "MII_PR_Patho_Specimen",
  "title" : "MII PR Patho Specimen",
  "status" : "active",
  "publisher" : "Medizininformatik Initiative",
  "contact" : [
    {
      "telecom" : [
        {
          "system" : "url",
          "value" : "https://www.medizininformatik-initiative.de"
        }
      ]
    }
  ],
  "description" : "Pathology specimen (based on Biobank module)",
  "fhirVersion" : "4.0.1",
  "kind" : "resource",
  "abstract" : false,
  "type" : "Specimen",
  "baseDefinition" : "https://www.medizininformatik-initiative.de/fhir/ext/modul-biobank/StructureDefinition/SpecimenCore",
  "derivation" : "constraint",
  "differential" : {
    "element" : [
      {
        "id" : "Specimen.id",
        "path" : "Specimen.id",
        "mustSupport" : true
      },
      {
        "id" : "Specimen.meta.lastUpdated",
        "path" : "Specimen.meta.lastUpdated",
        "mustSupport" : true
      },
      {
        "id" : "Specimen.meta.profile",
        "path" : "Specimen.meta.profile",
        "mustSupport" : true
      },
      {
        "id" : "Specimen.text",
        "path" : "Specimen.text",
        "mustSupport" : true
      },
      {
        "id" : "Specimen.accessionIdentifier",
        "path" : "Specimen.accessionIdentifier",
        "min" : 1,
        "mustSupport" : true
      },
      {
        "id" : "Specimen.request",
        "path" : "Specimen.request",
        "type" : [
          {
            "code" : "Reference",
            "targetProfile" : [
              "https://www.medizininformatik-initiative.de/fhir/ext/modul-patho/StructureDefinition/mii-pr-patho-service-request"
            ]
          }
        ]
      },
      {
        "id" : "Specimen.collection.method",
        "path" : "Specimen.collection.method",
        "min" : 1,
        "mustSupport" : true,
        "binding" : {
          "strength" : "extensible",
          "valueSet" : "https://www.medizininformatik-initiative.de/fhir/ext/modul-patho/ValueSet/mii-vs-patho-collection-method-snomed-ct"
        }
      },
      {
        "id" : "Specimen.collection.bodySite.extension:locationQualifier",
        "path" : "Specimen.collection.bodySite.extension",
        "sliceName" : "locationQualifier",
        "min" : 0,
        "max" : "*",
        "type" : [
          {
            "code" : "Extension",
            "profile" : [
              "http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-body-location-qualifier"
            ]
          }
        ],
        "mustSupport" : true
      },
      {
        "id" : "Specimen.collection.bodySite.extension:lateralityQualifier",
        "path" : "Specimen.collection.bodySite.extension",
        "sliceName" : "lateralityQualifier",
        "min" : 0,
        "max" : "1",
        "type" : [
          {
            "code" : "Extension",
            "profile" : [
              "http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-laterality-qualifier"
            ]
          }
        ],
        "mustSupport" : true
      },
      {
        "id" : "Specimen.processing",
        "path" : "Specimen.processing"
      },
      {
        "id" : "Specimen.processing.procedure",
        "path" : "Specimen.processing.procedure",
        "binding" : {
          "strength" : "extensible",
          "valueSet" : "https://www.medizininformatik-initiative.de/fhir/ext/modul-patho/ValueSet/mii-vs-patho-processing-procedure-snomed-ct"
        }
      },
      {
        "id" : "Specimen.processing:lagerprozess",
        "path" : "Specimen.processing",
        "sliceName" : "lagerprozess"
      },
      {
        "id" : "Specimen.processing:lagerprozess.additive",
        "path" : "Specimen.processing.additive",
        "type" : [
          {
            "code" : "Reference",
            "targetProfile" : [
              "https://www.medizininformatik-initiative.de/fhir/ext/modul-biobank/StructureDefinition/Substance"
            ]
          }
        ]
      },
      {
        "id" : "Specimen.container.type",
        "path" : "Specimen.container.type",
        "binding" : {
          "strength" : "required",
          "valueSet" : "https://www.medizininformatik-initiative.de/fhir/ext/modul-patho/ValueSet/mii-vs-patho-container-type-snomed-ct"
        }
      }
    ]
  },
  "text" : {
  }
}

XIG built as of ??metadata-date??. Found ??metadata-resources?? resources in ??metadata-packages?? packages.